LQ Marine – Leading Quality in Control Panel
NFPA 20 Electric-Driven Fire Pump Motor Controllers
For Marine, Shipping & Offshore Fire Protection Systems
LQ Marine is medium- and low-voltage electric-driven fire pump motor controllers are engineered specifically for NFPA 20 compliant fire water pump applications, serving offshore platforms, marine vessels, and industrial facilities.
Our controllers provide reliable, automatic fire pump starting, harsh-environment durability, and full compatibility with international classification standards.
Available voltage ranges include:
- 6.6 / 6.8 kV
- 7.2 kV
- 11 kV
- 13.8 kV
- Standard 380–690 V low-voltage models
Key Highlights
Fully Compliant with NFPA 20
- Designed to meet NFPA 20 Chapter 10 fire pump controller requirements
- Supports locked-rotor starting, no overload trips on main pump operation
- Automatic & manual starting functions per NFPA 20
- Fire-rated logic, fault-tolerant design
- Clear alarm, indication, and interlock philosophy
PLC-Based Control Flexibility
Enhanced performance through integrated PLC logic (selected models):
- Fast customization for client-specific logic, alarms, and interlocks
- Rapid response to project changes or emergency modifications
- Flexible communication with ship automation systems, DCS, or remote monitoring
- Modular function blocks for pump sequencing, remote command signals, and alarm automation
- Short lead-time for logic revisions and FAT modifications
Marine & Offshore Classification Support
Controllers can comply with:
- ABS
- BV
- DNV
- IEC
- CE Marking (optional)
Rugged and Reliable for Harsh Marine Environments
- Marine-grade corrosion protection
- IP44 / IP54 enclosures or custom engineered
- High short-circuit withstand ratings
- Designed for heat, humidity, vibration, and salt-laden atmospheres
- Continuous duty control electronics
MV Series Table
| Model | Voltage Level | Starting Method | Rated Power Range | PLC Option | Certifications / Options |
| LQ-FP-MV6 | 6.6–6.8 kV | ATL / Soft Starter | 150–1500 kW | Optional | NFPA 20, ABS/BV/DNV, IEC, CE |
| LQ-FP-MV7 | 7.2 kV | ATL / Soft Starter | 150–2000 kW | Optional | NFPA 20, ABS/BV/DNV, IEC |
| LQ-FP-MV11 | 11 kV | ATL / Soft Starter | 150–3500 kW | Optional | NFPA 20, ABS/BV/DNV, IEC, CE |
| LQ-FP-MV138 | 13.8 kV | ATL / Soft Starter | 200–4000 kW | Optional | NFPA 20, ABS/BV/DNV |
| LQ-FP-LV | 380–690 V | ATL / Soft Starter / VFD* | 15–450 kW | Standard | NFPA 20, CE, IEC |
*VFD for jockey or auxiliary pumps unless specially approved by AHJ for main fire pump.